Well in Normal start, you'd begin with engine no.2 start, and you'd use APU bleed air for that. You'd also use APU bleed air to start no.1 engine after no.2 is started.
But yes Isolation valve would be open.However it has its own logic for opening/closing while switch selector is in AUTO.