PPRuNe Forums - View Single Post - Piper Arrow 180 Help
View Single Post
Old 9th August 2011 | 12:21
  #16 (permalink)  
FlyingStone
 
Joined: Apr 2010
Posts: 1,320
Likes: 102
From: IRS NAV ONLY
Pilot DAR: The maximum continuous MP chart, which is part of Lycoming O-360 (IO engines included) operation manual suggests that Lyco IO-360-B1E engine can be operated continuously at 25"/2000 rpm or 23"/1800 rpm. Oversquare or not, it's what the engine manufacturer approved.
FlyingStone is offline  