Hi A33Zab,
Originally Posted by A33Zab
Exact! and the spikes @ 02:10:16 'CLOSING of the CAS monitoring window & ADR rejections'?
Well, not sure. In fact, I'd say that at around 0210:16, speeds could have been coherent again for a very short time and FDs were back, disapearing almost immediately. In between, a new set VSS was sampled, taking the actual value from the real V/S at this exact point.
CAS monitoring doesn't alter the VSS parameter (see 0210:05-0210:15 and subsequent values staying where they were while V/S increased or decreased). Its value freezes to the current V/S when FDs kicks off.
takata is offline