Bearfoil: The THS will move to satisfy long term trim solutions PROVIDED the `g` demand is not greater than -.5g ( namely -.6 to -1g ) or High Speed Protection is active. Once away from these constraints then it should resume movement if necessary.
HOWEVER manual movement of the THS is always available to the pilot and its authority is very large.