fcom 3
Fcom 3.03.26.
- BAT 1 and 2 and APU BAT OFF
Wait until the APU flap is fully closed (about 2 minutes after the APU AVAIL light goes out) before switching off the APU battery. Switching the batteries off before the APU flap is closed may cause smoke in the cabin during the next flight.
- SECURING THE AIRCRAFT CHECKLIST COMPLETE
Last edited by mutley320; 18th May 2011 at 11:45.