PPRuNe Forums - View Single Post - EGT OVERLIMIT at T/O: continue flight?
View Single Post
Old 23rd Jan 2011, 11:38
  #28 (permalink)  
GlueBall
 
Join Date: Jun 2001
Location: UTC +8
Posts: 2,626
Likes: 0
Received 0 Likes on 0 Posts
...Not necessarily a need for immediate shutdown and turn back.

...It should be covered under "alternate operations" in your QRH. Typically, it requires immediate thrust reduction to return EGT to within normal operating limits and to make a log entry of observed over temperature and duration.

"If EGT can be returned to normal, continue operation provided that there is no evidence of damage and all other engine parameters are normal."