Also I think you'll find that the 737NG FCOM volume 2 states (correctly) that, with a high service demand on that hydraulic system (with the EDP inop), the 'low pressure trip' for the A autopilot may occur momentarily, dropping out the autopilot, but can be immediately re-engaged.