Capt Groper
My understanding of the EBHA function is the same as yours, but I'm not a specialist either.
It seems the EBHA is supposed to shift from main hydraulics to local hydraulics under electric power in the case of main hyd system failure.
In short, spoiler #6 should have deployed if it had electrics.