Sequence valve in incorporated only on wing tank pumps so that the fuel is first fed from center tank and then the wing tanks . but when slats deployed its fed from its individual wing tanks....i do agree with remiers on this. After take off slats retracted in cruise mode again it will fed sequentially from center tank if present till low qty is triggered and pump gets off. SEE AMM or Fcom for more details....