There is a difference between no starter cut-out and start valve remains open.
With no starter cut-out the VOL 1 states "At 46% N2, verify that the Engine Start switch moves to Off. If not, move the Engine Start switch to Off. End of drill except read the MEL.
Start Valve remains Open is an entirely separate problem and dealt with via the QRH