PPRuNe Forums - View Single Post - Rat On A320
Thread: Rat On A320
View Single Post
Old 18th May 2010 | 17:01
  #3 (permalink)  
rudderrudderrat
 
Joined: Oct 2009
Posts: 1,270
Likes: 0
From: UK
Hi toby320,

An ancient scroll copy of FCOM says
"For GA -Proc refer to the ESS BUSES ON BAT procedure."

ELEC ESS BUSES ON BAT says:
If landing gear fails to retract during GA, when in Emergency Configuration, the emergency generator can be recovered as follows:

MIN RAT SPD = 180 kts
accelerate to 180 kts to recover RAT operation with the gear down.
LGCIU 1 CB (C09)... Pull
Pull LGCIU 1 cb to simulate the landing gear up condition, in order to allow emergency generator operation.
EMER ELEC PWR .. MAN ON
Allows coupling of the emergency generator.

Sounds like a pig's breakfast.
rudderrudderrat is offline  
Reply