Hi fredgrav,

Also there's a section on computer resets in the QRH, - page 2.44 which may be relevant.

"Loss of Fuel Quantity Indication OR
Simultaneous triggering of FUEL L TRANSFER VALVE CLOSED and FUEL R TRANSFER VALVE CLOSED, although system display indicates no anomaly."

Then it asks for 3 FQI cbs to be pulled and reset after 5 secs.

Edit. I gather that the FUEL L + R WING TKS LO LVL ECAM will be enhanced and harmonised with the rest of the Airbus Fleets, and will request "FUEL X FEED ON" (open) when the next Flight Warning Computer F6, is installed. (scheduled to be certified by the end of 2010) Which will make all the fuel available to the engine(s) until all the fuel on board is exhausted.

Last edited by rudderrudderrat; 1st May 2010 at 15:11. Reason: extra text