PPRuNe Forums - View Single Post - EC225 Shortcomings
View Single Post
Old 24th October 2009 | 16:53
  #24 (permalink)  
Training Centre
 
Joined: Aug 2008
Posts: 12
Likes: 0
From: Aberdeen
HC - ECF eventually acknowledged the problem and redesigned a relay in the electrical system. If the new relay is fitted the new RFM procedure works fine but, despite what the RFM seems to say, the battery should go on within 5 seconds of GPU authorisation, not after 5 seconds (ref. SA).
Training Centre is offline  