A pumps on a B732 were EDPs or Engine driven pumps...operated from the Engine & mounted on the gearbox.
The switches were placed on at all normal times to increase the life of the depressurising solenoid.
On the B733 onwards A & B system had one EDP & one EMDP [Electric motor driven pump] each.
regds