PPRuNe Forums - View Single Post - AF447
Thread: AF447
View Single Post
Old 12th Jun 2009, 18:35
  #1297 (permalink)  
Mad (Flt) Scientist
 
Join Date: Sep 2002
Location: La Belle Province
Posts: 2,179
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by madrock
However, none of these monitoring systems can detect a situation where the heater might be working perfectly, and yet unable to keep up with ice accretion in a particular environmental scenario due to a design flaw.
So is there any work being/can be done to address ?
The heater controller maybe can't tell when it's being overwhelmed by outside spec icing conditions (or an undetected heater failure or a "design flaw") but there is a system which can detect the consequences - the ADIRU miscompare messages are telling you that the data is beoming unreliable. Since there's not a lot you can do to rectify the situation other than switch to (hopefully functional) alternate sources.
Mad (Flt) Scientist is offline