PPRuNe Forums - View Single Post - RB211 FAFC Ignitor Selection (744)
View Single Post
Old 26th Apr 2009, 07:26
  #1 (permalink)  
NSEU
 
Join Date: Feb 2004
Location: Australia
Posts: 1,307
Likes: 0
Received 0 Likes on 0 Posts
RB211 FAFC Ignitor Selection (744)

I've been trying to figure this out for a few days now.

My notes tell me that the ignitors alternate after each "ground start" and that the ADC provides the air-ground signal. However, I can find no links between the PSEU and the ADC which would tell the ADC that it was on the ground.

The only air/ground signal that the ADC's seem to get is during a CMC test (and that requires the CMC Ground Test Switch to be on)... shown as "FT" on the schematics.

Anyone have a better knowledge of this selection process?

Thanks.
Cheers.
NSEU
NSEU is offline