PPRuNe Forums - View Single Post - (A)B 412 with collective stuck down....
View Single Post
Old 10th February 2009 | 16:57
  #11 (permalink)  
oldbeefer
25 Anniversary
 
Joined: Jul 2000
Posts: 794
Likes: 8
From: Wiltshire
chopper doctor

I think reading Ed's last post that there is no stick jump at idle - only when the Nr is above 80%. That's really got me beat. Also, a 25hr involves nothing on the control runs or hyd systems. Spoke to my engineers this afternoon and they can only think servo, but for the problem not to show below 80% is very strange.
oldbeefer is offline  