For something a little newer, B777 APU shutdown as part of before taxi procedure and started as part of after landing procedure. It can be used in flight as needed for electrics up to service ceiling and for bleed up to 22.000 ft. It also automatically starts with the loss of both electrical transfer busses in flight.