The flap control unit(computer) on the 45 constantly monitors the flap system for faults and failures including asymmetry via RVDT's . If the unit detects a split in flap deployment of more than 3.8 to 7.45 degrees , depending on flap speed , the system will be disabled and a big amber 'FLAPS FAIL' will be posted on the EICAS .