PPRuNe Forums - View Single Post - 744 RB211 Fire Loops - Time Delay?
View Single Post
Old 16th October 2008 | 21:45
  #3 (permalink)  
N1 Vibes
 
Joined: Oct 2003
Posts: 577
Likes: 0
From: Gweriniaeth Cymru
cheers spanners,

finally got the answer from Boeing:

A fire detected on one loop is annunciated as a 'full fire', as soon as a fire OR fault is detected on 2nd loop

There is a 20 second buffer in Loop Fault indications.

Many thanks,

N1 Vibes
N1 Vibes is offline  
Reply