BATTERY SWITCH (Battery Bus Switch)
-the battery switch must be
ON to power the battery bus except......
- the battery bus can be powered with the BAT switch off by moving the Standby power switch to the BAT position.
BATT SWITCH OFF
- removes power from the battery bus and switched hot battery bus when operating with normal power sources available (standby power switch in
OFF or the
AUTO position)
-removes power from the switched hot battery bus,battery bus,static inverter,AC Standby Bus,DC Standby Bus when battery(s) are the only power source
BATT SWITCH ON
- energizes battery bus, switched hot battery bus and electrical meters module on the overhead
P5 Panel
- energizes relays that provide automatic switching of standby electrical system (bat bus,static inverter,AC & DC Standby buses) to battery power with loss of normal electrical power.
Hope this Clears things up for you
B1 and Electron Free