PPRuNe Forums - View Single Post - A320 Center Tank Fuel
View Single Post
Old 5th Jul 2008, 08:40
  #22 (permalink)  
Aikon
 
Join Date: Aug 2005
Location: Malaysia
Posts: 37
Likes: 0
Received 0 Likes on 0 Posts
captain87 - That's not the reason. The Fuel recirculation to IDGs is automatically inhibited during take off & climb. FCOM 1, 1.70.40, page 6.

flyr767 - Yes, agreed. The exception is for obvious reason that it does not alert the pilots unnecessary during high workload period and it is not for the reason of contamination.
Aikon is offline