B777fly
All of the boost and ovrd/jett pumps on the aircraft are centifugal pumps. The air and fuel separation occurs as a result of pump action. The inlet to the pump is screened at the pump pickup point.
The outlet of the pumps have check valves installed. Fuel goes out of the pump but nothing can return through the pump.