To contaminate both engines with center tank fuel you will need to have either one pump running and an opened X-feed, or the 2 CT pumps running.
In case the crew didn't switch off those pumps, they are supposed to switch off automatically in low press situation. Would it be possible for those pumps to restart in case liquid fuel would become available ?