Our SOP's are:
1. Icing in descent - Inner wind de-ice is seclected on for one minute after ice detect light has extinguished.
2. When holding in icing conditions, Inner wing de-ice should be on for 1 minute at 8 to 10 minute intervals.
3. Inner wing de-ice must be on if airframe anti-ice is on before selecting flap18