PPRuNe Forums - View Single Post - A320family braking logic question
View Single Post
Old 21st Sep 2007, 15:15
  #9 (permalink)  
sergejv
 
Join Date: Aug 2007
Location: EVRA
Age: 50
Posts: 8
Likes: 0
Received 0 Likes on 0 Posts
1.BSCU with ADIRU data control breaking systems.
Alternate braking is automatically obtained :
- in case of green pressure loss,
- if a failure occurs on the normal braking system during operation or BSCU test.
Also you can switch manual to Alternate by set A/SKID & N/W STRG Switch to Off.

When on Alternate and Yellow Eng pump is inop the accumulator only supplies the brakes.
With the accumulator pressure only, a maximum of 7 full brake pedal applications can be performed.
sergejv is offline