PPRuNe Forums - View Single Post - Single-engine taxiing
View Single Post
Old 18th Aug 2007, 15:12
  #14 (permalink)  
SIDSTAR
 
Join Date: Jun 2005
Location: Citizen of the World
Posts: 174
Likes: 0
Received 0 Likes on 0 Posts
Whyjelly,

Airbus has just changed the order of the procedure to read APU on, then Eng 2 shutdown, then Y Hyd pump on. Eng shutdown and Yellow pump on have been reversed due to a possible problem with the pump shutting down during the electrical changover and not coming back on line when the APU is on the bus.
SIDSTAR is offline