Whyjelly,
Airbus has just changed the order of the procedure to read APU on, then Eng 2 shutdown, then Y Hyd pump on. Eng shutdown and Yellow pump on have been reversed due to a possible problem with the pump shutting down during the electrical changover and not coming back on line when the APU is on the bus.