IMHO ,it doesn't disconnect TR1 from TR2 ,it disconnects DC bus 1 from DC bus 2.
Indeed you may say the TR supply the DC bus,but this is what the FCOM say,it disconnects DC bus1 and 2.
And it is called TR cause it is used to connect TR3 to DC bus 1 if TR1 fails.