Originally Posted by CAT III DUAL
......Furthermore:
"It had been found that the contents
of a Static Read-Only-Memory (SRAM) component
could alter and that this would result in a GCU
‘Failsafe’ fault and isolation of the associated IDG
from the electrical system."
Conclusion:
Due to the failed SRAM, any IDG available was rejected finally
and associated buses were lost.....
The report wrongly writes Static Read-Only-Memory (SRAM).
It should read ROM Read-Only-Memory or
Static Random-Access-Memory (SRAM)

Can someone clear this up !?
.
.