Feather #3.

Yes, ADP overspeed trip is as per the classic. Maint Manual states that it is permissible to reset the turbine drive overspeed 'once'. We normally read that as "each engineer" can reset it 'once'. Bill can reset it once, Tony can reset it once, George can reset it once, Paul can reset it once etc, etc until a spare can be sourced. It's all in the interpretation!

It's easy to do, access the ADP Turbine Drive, remove the cap on the overspeed housing (3/4 spanner I think) and push in the silver pin on the inside.
Spanner Turner is offline  