PPRuNe Forums - View Single Post - A 319 decellerated APP
View Single Post
Old 16th September 2006 | 10:33
  #1 (permalink)  
Speevy
20 Anniversary
 
Joined: Oct 2002
Posts: 1,425
Likes: 0
From: ----
A 319 decellerated APP

Hi guys, I need some help from more experienced guys out there...
My company wants me to be fully conficured ,at Vapp ,with engine above idle and established by 1000ft.
No big deal you would say but for me recently it hasn't been that easy.
In the place where I operate it happens many time that during your app you will have some tailwind which makes it a bit harder if you use the normal references (config 1 at green dot, within 3 miles of FAF, and S speed by 2000ft TDZE with F2 extension by that height and then continous selection of gear and flaps.)
By reading OM and FCOM I realize that if decelaration toward S speed doesn't seem to be happening by 2000ft L/G should be selected!
Do you have any operating tips that I could use?
Any help will be apreciated..
Thanks in advance.
Speevy
Speevy is offline  
Reply