A check valve as stated prevents fluid flowing in the wrong direction (also known as a one way valve)
A priority valve cuts off fluid to a heavy user in the system in the event of low quant. or press. thus keeping the avail. fluid press. for essential systems(ie. gives priority to essential systems)
Brgds