WP,Thanks for the reply,sorry to be pedantic but the QRH says,if engine fire warning received rotate engine fire SWITCHES to the affected engine.IE Left fire warning left switch left, right switch left.It does not say SWITCH.Thats the point.The eng fire on gnd drill says both bottles into the affected engine, total common sense.Its this evac drill with a fire wx that doesnt sit well with me.
Regards Max.