Mach Transducers
The CRJ mach transducers display the equivalent mach on the PFDs. Climbing, it is first displayed at an equivalent mach value of .45 and above. Descending, mach is removed at .40.
This is clearly, I suggest, the misplacement of a 'decimal'.