PPRuNe Forums - View Single Post - AA 587 Final Report
View Single Post
Old 13th Dec 2004, 10:58
  #27 (permalink)  
Groundbased
 
Join Date: Apr 2002
Location: In the circuit
Posts: 177
Likes: 0
Received 0 Likes on 0 Posts
Rananim,

It was the vertical stabiliser that separated, and according to the conclusions of the NTSB report, at loads that were:

"about twice the certified limit design envelope and were more than the certified ultimate load design envelope"

GB.