Just to elaborate a bit....... or confuse
On the ground:
The control column controls the elevator and the 'pickle' switches control the stab.
In the air:
The control column, stab 'pickle' switches, and auto pilot all control the elevators with the elevator offload a calculated function from the PFC's of airspeed and roll attitude, active after a time delay moves the stabilizer to null the elevator.