- about 10 uncommanded firings confirmed across a range of winch/airframe combinations.
- hazard analysis shows required for maritime ops. Not required for overland ops
- pyrotechnic hand held ( single Hand ) cutters are available. Most signed off on 600 lb hoists due to single hand cutters not effective on the 3/16th cable. 300 lb hoists generally using parrot beak cutters with enhanced entry assistance hook mounted on boom.
- number of operators have alternate systems risk analysed and signed off
- various risk mitigators in place for operational and training requirments using both hand held and pyro cutters.
- most winches now at latest mod state for EMI and pyrocharge now requires significant current to fire. (5 amps I think)
- equivalent levels of safety have been demonstrated to CASA's engineering and operational satisfaction.
- some govt agencies staff refuse to be winched over land with pyro cutters installed. They (DTWM and aircrew) accept the hand held situation as being the best compromise.