I don’t think your instructor is right. The APU bleed valve closes when the APU is below 95% even if the bleed pb is on. With the crossbleed valve in Auto it closes when the APU valve closes (valve position not PB position).
More importantly though… Why would your instructor be teaching you to ignore the published crossbleed start procedure in favour of making up your own?