PPRuNe Forums - View Single Post - EC120
Thread: EC120
View Single Post
Old 31st May 2024 | 22:51
  #606 (permalink)  
chopchopper
 
Joined: Nov 2021
Posts: 1
Likes: 0
From: Sydney
T45 conformation box

we had the same problem and replaced the circuit board in our T45 conformation box- fixed the problem!

thanks to those who contributed to this forum 20 years ago who provided the answer!

Originally Posted by 3top
Hello everyone,

I though you might be interested how we finally fixed our T45 temp problem:

It was the Confirmation box!!

The bad news is, it was a intermident failure! The "fun" part being the -intermident-!!
You check the damn thing according to the maintenance manual it checks out just fine!

The final tip came from Australia - thanks Frogspawn!!

After a couple of e-mails across the world with some Turbomeca-techs, we eliminated all possible causes. Actually nothing was left!

In Australia there was a similar case so we just gambled on it! Voila!
Also considering the normal prices in this business, the confirmation box is a rather lowprice item!

Thanks again for all the tips!

Frogspawn, your man came up with the right idea!!

3top
chopchopper is offline  
Reply