Originally Posted by
mrdeux
If you take the power away, they fail ‘open’.
No, if you take power away the fuel shut off valves (SOVs) stay in the position they were in when power is removed. In normal operation that would be open but could be closed or even somewhere between if the vave was moving at the time of power loss. The fuel SOVs are motorised not pressure operated.