Originally Posted by leffsu
How to understand the fixd temp?If the ACSC 2 fault, then I select the cockpit temp to higher. Does it will affect the cabin zone temp?
Or how does the FIXED TEMP calculated?
From diagram FCOM DSC-21-10-10 General

If ACSC 2 is at Fault, then Pack 2 will shut down and Pack 1 will go to high flow (single pack operation).
ACSC 1 will command a temperature output from pack 1 based on the coldest temperature demand in Zone 1. (Fixed temperature). Additional warm trim air will flow into the cockpit air duct to help regulate the temperature.

The cabin will only be receiving the air supply from pack 1 without any warm trim air so it will feel colder than the cockpit.