PPRuNe Forums - View Single Post - Single engine taxi, yellow electric pump
View Single Post
Old 1st May 2023 | 04:54
  #9 (permalink)  
Black Pudding
15 Anniversary
 
Joined: Apr 2011
Posts: 487
Likes: 42
From: Doha
Originally Posted by Amadis of Gaul
You may be misreading the procedure. Ours says there have to be four conditions met before shutting down engine #2 after landing. These 4 being:

1. After landing check complete;
2. Cooldown period complied with (if necessary);
3. APU AVAIL light is on (because our birds don't have that much-discussed mod);
4. Aircraft moving in a straight line.

Once all those are met, THEN you go into the Engine 2 shutdown flow, which is Y pump on, engine A/I off, master off.

The reason we were given for #4 is that during power transfer it is possible for the BSCU to momentarily lose power, thus rendering you brakeless (again, momentarily) which would be a bad thing in a turn. Whether that's a legitimate concern I know not.
Is it not ENG 2……SHUT DOWN then Y ELEC PUMP…..ON
Black Pudding is offline  
Reply