Originally Posted by
JimEli
automatic blade folding
Blade fold is driven by electric motors in the spindles, not hydraulically by the dampers..
The BH has independent dampers. The NH has all 4 connected to a common reservoir under the beanie. Not familiar with the system, don't know if a broken line can pump all 4 dampers dry.