I don't have any info on the 747-8 but on the 744 control of the Hyd Demand Pumps is via DC while the pump motors themselves are 3 phase AC powered. So if you lose DC Bus 2 you lose control of the Demand Pump 2. Expect the 747-8 to be similar.