PPRuNe Forums - View Single Post - A320:Smoke Procedure
View Single Post
Old 2nd Feb 2022, 11:48
  #5 (permalink)  
stalwart2010
 
Join Date: Aug 2010
Location: Cloud no.9
Posts: 22
Likes: 0
Received 0 Likes on 0 Posts
Originally Posted by CrazyStuntPilot
From a conversation I had with Airbus a while ago:


The condition: "If smoke disappears within 5 minutes: NORMAL VENTILATION . . . . RESTORE" requests the flight crew to restore the ventilation system if the smoke disappears within a 5-minute timeframe after the smoke is detected.
The items to restore are the pushbutton switches on the VENTILATION overhead panel: BLOWER, EXTRACT, CAB FANS.

Thank you for your reply
.So I understand that 5 mins timing is only applicable to Avionics smoke procedure after the initial actions? or its applicable to other sources ie)packs and cabin equipment?The way this precondition is placed in the QRH is a bit confusing.
stalwart2010 is offline