PPRuNe Forums - View Single Post - Hydraulic system loading
View Single Post
Old 16th Jan 2022, 02:09
  #49 (permalink)  
CCA
 
Join Date: Oct 1999
Location: Up there
Posts: 202
Likes: 0
Received 0 Likes on 0 Posts
Re Boeing “gear down, flap XX” from memory there’s a priority valve in the flap power control package that gives priority to the gear should the pressure drop below 2000psi, with two hydraulic pumps running this likely never occurs. With one then you may notice the flaps moving slower / stopping until the gear is down and locked and the pressure returns adequately to run the flaps.


Last edited by CCA; 16th Jan 2022 at 05:23.
CCA is offline