FWIW I’ve contemplated something similar for an oil leak coming back from Sao Paolo. The plan was to shut the engine down once the oil reached a certain level allowing for a restart in the descent to have all engines operating for the approach. As it transpired the leak slowed as the quantity decreased meaning we never reached the quantity we nominated for shutdown.