PPRuNe Forums - View Single Post - A 320 Engine Relight
View Single Post
Old 20th August 2020 | 15:32
  #2 (permalink)  
sonicbum
10 Anniversary
 
Joined: Mar 2012
Posts: 2,605
Likes: 154
From: Having a margarita on the beach
Originally Posted by Boyington
For CFM 56 engines in the Engine Relight Section of the QRH it states Windmill Quick Relight if N2 >12%. whereas for LEAP engine, it states Windmill Quick Relight t < 20 s. What does T < 20 S mean.
Thanks
Not flying/doing SIMS on the NEOs but I have access to the manuals and my take is the answer could be in the FCOM - PRO - ABN - ENG RELIGHT note at the bottom.

Note:
For an in-flight restart, the FADEC decides whether the rotor speed is sufficient to perform a windmill relight or needs assistance from the starter in view of the current engine parameters and the flight environment parameters. Within the windmill quick relight envelope, if the crew is using the Quick Windmill Relight procedure, the FADEC will restart the engine after the flight crew cycles the ENG MASTER lever from "ON" to "OFF" then back to "ON".


Possibly this cycle has to be within 20 seconds to use the Quick Windmill Relight ?

sonicbum is offline  
Reply