The chances to end up in mechanical backup are so remote that EASA does not even require any flight training in mechanical backup during the type rating or recurrent training. And i guess that is the reason behind the design. To move the rudder you need in any case hydraulic power, hence the three system connection. For the elevator you have, as so eloquently described above, usually either one side and the THS powered, or both sides on the blue system.