After green hydraulic loss.Aircraft returns while taxiing to gate APU started and Hydraulic fluid invested into APU inlet.
this causes white smoke/fumes after engines shutdown due packs now running off bleed air.
maybe airbus need to rewrite the QRH.
Full system hydraulic loss don’t Select APU bleed ON.
external power on arrival if available.